All nodes are configured with BMC ip address. Below is the table with all IP address (Including the compute nodes of the Power Edge M1000e)
Adding Dell Networking N2048 Switch management IP address. This is the BMC network all nodes will be using for IPMI communications.
Connect to the switch using the console and issue the following commands
| Node Names | BMC IP's |
|---|---|
| bright1 | 172.17.0.1 |
| bright2 | 172.17.0.2 |
| login01 | 172.17.0.3 |
| login02 | 172.17.0.4 |
| sched | 172.17.0.5 |
| imlnode | 172.17.0.6 |
| nfs01 | 172.17.0.7 |
| nfs02 | 172.17.0.8 |
| mds01 | 172.17.0.9 |
| mds02 | 172.17.0.10 |
| oss01 | 172.17.0.11 |
| oss02 | 172.17.0.12 |
After plugging nodes on the switch, bright discovers mac address through switch ports
[bright1->device]% newnodes MAC First appeared Detected on switch port -------------------- -------------------------------- ---------------------------- 10:98:36:B5:66:93 Fri, 11 Aug 2017 17:51:00 SAST switch01:2 10:98:36:B5:66:A3 Fri, 11 Aug 2017 17:51:29 SAST switch01:3 10:98:36:B5:66:1F Fri, 11 Aug 2017 17:51:29 SAST switch01:4 10:98:36:B5:6D:DB Fri, 11 Aug 2017 17:51:59 SAST switch01:5 10:98:36:B5:6A:FF Fri, 11 Aug 2017 17:51:59 SAST switch01:6 18:66:DA:94:D4:33 Fri, 11 Aug 2017 17:51:59 SAST switch01:7 18:66:DA:94:D8:D1 Fri, 11 Aug 2017 17:51:00 SAST switch01:8 18:66:DA:94:D3:8B Fri, 11 Aug 2017 17:51:29 SAST switch01:9 18:66:DA:94:D2:C1 Fri, 11 Aug 2017 17:51:29 SAST switch01:10 84:7B:EB:F5:CA:46 Fri, 11 Aug 2017 17:51:59 SAST switch01:11 84:7B:EB:F5:D9:02 Fri, 11 Aug 2017 17:51:59 SAST switch01:12
For each node the following is done. Only the procedure for adding “sched” is shown below. “sched” node is connected on switch port 5:
Define “sched”
[bright1->device]% add physicalnode sched [bright1->device*[sched*]]%
Link the node to the switch port
[bright1->device*[sched*]]% set ethernetswitch switch01:5
Configure IPMI Interface
[bright1->device*[sched*]]% interfaces [bright1->device*[sched*]->interfaces]% add bmc ipmi0 Switched power control for this node to: ipmi0 [bright1->device*[sched*]->interfaces*[ipmi0*]]% set network ipminet [bright1->device*[sched*]->interfaces*[ipmi0*]]% set ip 172.17.0.5 [bright1->device*[sched*]->interfaces*[ipmi0*]]% exit
Configure Ethernet interface called “bootif”
[bright1->device*[sched*]->interfaces*]% add physical BOOTIF [bright1->device*[sched*]->interfaces*[BOOTIF*]]% set network internalnet [bright1->device*[sched*]->interfaces*[BOOTIF*]]% set dhcp yes [bright1->device*[sched*]->interfaces*[BOOTIF*]]% exit
Configure Infinabnd Interface
[bright1->device*[sched*]->interfaces*]% add physical ib0 [bright1->device*[sched*]->interfaces*[ib0*]]% set network ibnet [bright1->device*[sched*]->interfaces*[ib0*]]% set dhcp yes [bright1->device*[sched*]->interfaces*[ib0*]]% exit
List defined Network interfaces
[bright1->device[sched]->interfaces]% list Type Network device name IP Network ------------ -------------------- ---------------- ---------------- bmc ipmi0 172.17.0.5 ipminet physical BOOTIF [prov,dhcp] 172.18.0.221 internalnet physical ib0 [dhcp] 0.0.0.0 ibnet [bright1->device[sched]->interfaces]%
NB: ib network ip is issued when OFED is installed. Click Infiniband Configuration to view the steps
Set provisioning Interface
[bright1->device*[sched*]]% set provisioninginterface bootif
Set node category. (node categories are linked to software images)
[bright1->device*[sched*]]% set category scheduler
Commit all the chages
[bright1->device*[sched*]]% commit
The node begins to install after the “commit” command
| Node Names | BMC IP's |
|---|---|
| cnode01 | 172.17.0.15 |
| cnode02 | 172.17.0.16 |
| cnode03 | 172.17.0.17 |
| cnode04 | 172.17.0.18 |
| cnode05 | 172.17.0.19 |
| cnode06 | 172.17.0.20 |
| cnode07 | 172.17.0.21 |
| cnode08 | 172.17.0.22 |
| cnode09 | 172.17.0.23 |
| cnode10 | 172.17.0.24 |
| cnode11 | 172.17.0.25 |
| cnode12 | 172.17.0.26 |
| cnode13 | 172.17.0.27 |
| cnode14 | 172.17.0.28 |
| cnode15 | 172.17.0.29 |
| cnode16 | 172.17.0.30 |